Wood Processing Dust Removal and Cooling Spray System, Textile Workshop Cooling and Dust Removal Spray Machine, Printing Workshop Spray Dust Suppression System
Other Products
Wood Processing Dust Removal and Cooling Spray System Textile Workshop Cooling and Dust Removal Spray Machine Printing Workshop Spray Dust Reduction System
, Intelligent Controller: Utilizes digital chip control, integrating automatic control of upper and lower liquid levels and pressure; offers three working modes: automatic, manual, and remote control; includes protection functions such as overload, no-load, phase loss, and ultra-low voltage; features a no-load restart function, adjustable from 1 to 240 minutes; has a fault memory function, allowing review of the last 5 fault causes; easy installation and simple debugging.
2. Multi-Stage Pump: The pump must be filled with water before starting; the outlet valve must be opened during startup to reduce the motor's starting load and prevent motor burnout; when the pump's operating pressure decreases, the number of paper gaskets between the pump body and cover can be reduced; adjusting pressure too high may burn out the motor.
3. Water Tank: The tank is equipped with an automatic water level control valve. When the water level is insufficient, the switch opens to automatically replenish the water source; when the water level reaches a certain height, the control valve automatically closes to stop water replenishment. Enclosure Spray Features
1. Utilizes digital chip control, integrating automatic control of upper and lower liquid levels and pressure.
2. Offers two working modes: automatic and manual.
3. Includes protection functions such as overload, no-load, phase loss, and ultra-low voltage.
4. Features a no-load restart function, adjustable from 1 to 240 minutes.
5. Has a fault memory function, allowing review of the last 5 fault causes.
6. Easy installation and simple debugging. Construction Sequence
1. Pipeline Laying: The main water switch is set at the starting point, with the main pipeline set to 4 meters. Use tees to connect both ends of the water pipe, insert a spray pipe section above, and install a straight connector to link the nozzle to the pipeline. (The distance between spray pipes can be set according to actual needs.) The water pipe is fixed to the enclosure with clamps and screws.
2. Water Pump Installation: First, secure the water pump to the bracket with screws. After connecting the wires, cover the pump with a rain shelter and fix it to the bracket with screws. Wrap raw silk tape around the pump接头, then secure the water pipe to the pump接头 with screw clamps. The other end of the pump and pipeline接头 should also be wrapped with raw silk tape before connecting to the pipeline.
| Industry Category | Machinery |
|---|---|
| Product Category | |
| Brand: | 陆雄 |
| Spec: | LX280 |
| Stock: | 100 |
| Manufacturer: | |
| Origin: | China / Shandong / Jinanshi |